Highflow Filter Housings
The cost-effective housing solution when liquid flow rates exceed 200 m3/hr

When liquid flowrates exceed 200 m3/hr for particulate removal applications standard pleated cartridge filters (2½” dia) means that high numbers of cartridges have to be used. To solve this challenge the Highflow (6" dia) cartridge was introduced along with the PVH High Flow Housings. A single Highflow cartridge replaces 8 to 10 standard diameter cartridges with a reduction in filter housing footprint, reducing cartridge change out times and reducing the number for filters to be disposed of once used.
The PVH range includes single and multi-cartridge filter housings suitable for industrial liquid applications and caters for flows from 200 m3/hr up to 1,400 m3/hr. The housings are available in vertical or horizontal orientation to make installation of high flow cartridges as easy as possible.
Why Choose PoreFiltration?
-
Extensive product range
-
Best Price GUARANTEED!
-
Specialist support team with deep knowledge of liquid & gas applications
-
Reliable quality and delivery.
Technical details
-
Filter Material - 316 St.St.
-
Available lengths: 40.0", 60.0"
-
No of cartridges housed - 1, 3, 5, 7, 12
-
Typical flowrates - 100m3/hr to 1,400 m3/hr
-
Inlet/outlet connections - 3”- 12” Flange or butt weld
-
Cartridge mounting style - SOE (HFU industry standard)
-
Closure type options - Vee clamp/Flanged & Bolted or Rathman clamp
-
Surface finish options - Electropolished/Pickle, passivated & bead blast
- Design codes - PED, ATEX
Applications
- Municipal water applications
- Boiler feed
- Reverse Osmosis (RO) membrane protection
- Process Water in factories
Technical details [Product A]
Filter Medium | Polypropylene |
Available Lengths |
9.75" (24.8cm), 10.0" (25.4cm), 20.0" (50.8cm), 30.0" (76.2cm), 40.0" (101.6cm) |
Available Micron Ratings |
0.5, 1,3, 5, 10, 20, 30, 50, 75, 100μm |
Internal Diameter |
1.1" (28mm) / 4.5" (114mm) |
External Diameter |
2.5" (63mm) |
Max Operating Temperature | XX degrees |
Maximum Differential Pressure |
60psid @ 70°F (4.1 Bar @ 30°C) 50psid @ 122°F (3.4 Bar @ 50°C) 30psid @ 158°F (2 Bar @ 70°C) 15psid @ 180°F (1 Bar @ 82°C) |
Recommended Changeout Differential Pressure |
37psid (2.5 Bar) @ 30°C |
Regulatory |
All filter bags are supplied free of Silicone. FDA Approved. EU XXX. |
Datasheets |
Other Related Products
Bag Filters - Industrial & Food Grade
Industrial & food grade High-performance bag filters removing sediments, particulates, gels, corrosion products in all liquids.
Multi Cartridge Industrial Housings
St.st housing range for liquid industrial and steam applications. Flows between 1 to 200 m3/hr, pressure rated between 8 and 40 bar in single or muilti filter cartridge design.
Industrial Bag Filter Housings
St.st. housing range suitable for industrial liquid applications. Flows between 5 to 60 m3/hr in single or muilti filter bag designs. Pressure rated to 10 bar.
Frequently Asked Questions
A High Flow Filter Housing is a large-capacity, pressure-rated vessel designed to hold specially designed high flow filter cartridges. These cartridges have a larger diameter (6 inch) than standard filters (2 ½ inch), allowing them to process high volumes of liquid with fewer elements. The housing is engineered to reduce the housing footprint and reduce maintenance time because of less cartridges to change.
High Flow housings significantly reduce the number of cartridges needed for large systems, lowering labour and replacement costs. They also offer:
- Higher flow rates per filter
- Reduced system downtime when changing filters
- Smaller overall housing footprint
These housings are ideal for industries that require high throughput and consistent quality, including:
- Water treatment: For pre-filtration and RO protection
- Power generation: For cooling tower water and boiler feed
- Food and beverage: For product water, ingredients, and final filtration
Materials are chosen based on application demands and chemical compatibility.
Common options include:
- 316L stainless steel for corrosive and hygienic environments
- 304 stainless steel for general-purpose use
- GRP sea water or brackish water conditions.
View our Stainless Steel Filter options.
Yes, when constructed from materials like stainless steel for the highflow filters as well as the housings, temperatures up to 300°C can be handled.
Always check the specific housing rating, as temperature resistance also depends on the type of seals used.
Most models are designed to operate at pressures of 10 bar or below. It is not common to find these housings available for higher ratings. However with boiler condensate applications higher pressure ratings are used.
Yes.
- Vertical housings are easier for draining and changing cartridges and are often preferred where space allows.
- Horizontal housings are used in low-ceiling or restricted-access installations. The orientation depends on flow design, maintenance access, and site layout.
Regular maintenance includes:
- Monitoring differential pressure to track filter service life
- Replacing filter cartridges at the recommended pressure drop, typically 2.5 bar (35 psi)
- Regularly inspecting O-rings, seals, and housing integrity at every filter changeout
- Cleaning the vessel internally if fouling or scaling occurs
- Lubricating seals during reassembly to ensure leak-free operation
With correct operation and maintenance, high-quality stainless steel housings can last 10+ years. Lifespan depends on the operating conditions, cleaning protocols, and chemical exposure. Plastic housings may have shorter life expectancy due to the corrosive nature of sea water or brackish water applications.
Explore Related Articles
Talk to us today about your filtration requirements
-
Extensive product range
-
Best Price GUARANTEED!
-
Specialist support team with deep knowledge of liquid & gas applications
-
Reliable quality & delivery